Access to enclosed shopping centre car parks for LPG vehicles will depend on both the operator’s safety infrastructure and the vehicle’s documents. According to Uzmanpara, the general restriction on enclosed car parks will remain, with an exemption envisaged for shopping centre car parks that meet the required standards and obtain the necessary approvals. This does not mean all shopping centre car parks will open unconditionally to LPG vehicles.
Under the conditions described in the report, finding a shopping centre that accepts LPG vehicles will not be enough. The vehicle’s LPG fuel system must be recorded on its registration document, and its inspection must remain valid. Authorised car park staff will check compliance at entry and exit. Vehicles without an LPG entry on their registration document or a valid inspection will be refused access even to approved car parks.
A sign measuring at least 90×60 centimetres and bearing the TS 9881 conformity mark must be placed at the entrance where drivers can see it. However, a sign alone will not be sufficient for admission; the operator must also meet the technical and administrative requirements.
There will also be limits on where vehicles can park. Areas used by LPG vehicles cannot be below the first basement level, and those areas and their entrances and exits must be separate from sections used by other vehicles. Even at an approved shopping centre, therefore, not every level of the enclosed car park will be open to LPG vehicles. Under the regulation described by Uzmanpara, operators’ obligations extend beyond obtaining certification. Electrical and ventilation installations in enclosed car parks designated for LPG vehicles must be spark-protected, or Ex-proof. This requirement will apply alongside gas detection and extraction systems.
Ventilation must operate automatically in response to devices that detect LPG gas accumulating at ground level. The system must also have sufficient capacity to remove accumulated gas. The report says these measures are intended to reduce the safety risks arising from gas accumulation in enclosed spaces.
The report also sets out specific rules for floor drainage. A suitably sloped drainage channel system must be installed, but grates will not be permitted in these areas. Drainage outlets must have trapped chambers that prevent gas from passing through. Assessments of a car park’s compliance will therefore cover its drainage infrastructure as well as the areas where vehicles park. According to the report, the exemption may apply to enclosed car parks at shopping centres covered by the Regulation on Shopping Centres, published in Official Gazette No. 29636 on 26 February 2016. The general restriction on enclosed car parks must therefore be distinguished from the conditional access permitted at shopping centres.
Operators must meet the requirements for Type 1 commercial car parks specified in the TS 9881 standard. A service qualification certificate from the Turkish Standards Institution and approval from the local fire service are also listed as mandatory conditions. Enclosed shopping centre car parks that fail to meet these requirements will not be allowed to admit LPG vehicles.
Compliance monitoring will not end with the initial approval. Authorities empowered to issue business opening and operating licences will keep records of car parks that admit LPG vehicles. These car parks will be inspected annually, either directly by the competent authorities or through inspections they commission. Operators will therefore also be obliged to maintain the required technical conditions.
Uzmanpara reports that the Building Fire Regulation was published in the Official Gazette dated 27 November 2026, with an effective date of 1 January 2028. According to the timetable in the report, the conditions will begin to apply on that date. The reported timing and scope should therefore not be interpreted as immediate, unconditional access to all enclosed car parks.
The same report says the general restriction in Article 60 of the regulation covers vehicles with LPG and compressed natural gas (CNG) fuel systems. The specific conditions for admission to shopping centre car parks, however, are described in terms of LPG vehicles.
No. According to the report, the vehicle must also have LPG recorded on its registration document and a valid inspection. Authorised car park staff will check these requirements.
No. Areas designated for LPG vehicles cannot be below the first basement level. These areas and their entrances and exits must be separate from the other car park sections.
Key entry requirements
The checks that matter for drivers
Safety requirements cover ventilation and drainage
Certification and annual inspection obligations for operators
What implementation date does the report give?
Frequently asked questions
Does a car park’s approval mean every LPG vehicle can enter?
Will LPG vehicles be able to use every level of a shopping centre car park?

